Version 4.6.7.1
Release date: 2020-08-11
Server changes:
- Support for dynamic carousel updates. Carousel bit rate and pids
(carousel pid, ait pid, stream event pid) can be changed without
restarting the carousel.
- Updating carousel parameters for a running carousel does not any more cause PMC or Web console to freeze for a long time.
PMC changes:
- Added simple application boundary descriptor to AIT descriptors.
Webconsole changes:
- Validation when adding or modifying user.
Version 4.6.7.0
Release date: 2020-07-20
Server changes:
- Exporting settings to XML now quotes field names in INSERT
statements, allowing export of tables with fields containing capital
letters, e.g. createdAt.
Webconsole changes:
- Webconsole now has users and roles.
Version 4.6.6.0
Release date: 2020-05-26
Server changes:
- Support for SSU proprietary profile.
PMC changes:
- Support for SSU proprietary profile.
- Remember last XML import and export dirs.
- (JRE upgraded form jre1.6.0_17 to jre1.8.0_251 (jre-8u251-windows-x64), change postponed)
Webconsole changes:
- Added webconsole to CentOS 7. Uses node-v12.16.3.
Version 4.6.5.4
Release date: 2020-04-29
Server changes:
PMC changes:
- PMC: Fix PMT definitions application_type bitcount from 16 to 15 in Application.
Version 4.6.5.3
Release date: 2020-04-24
Server changes:
- On CentOS 7 fix for vstrf format string problem.
PMC changes:
- Show modified times for carousel files correctly.
Webconsole changes:
- Show modified times for carousel files correctly.
Version 4.6.5.2
Release date: 2020-04-06
Server changes:
- On CentOS 7 OS: Muxer UDP TS output stream does not stop if system time is set to earlier.
- On CentOS 7 OS: Muxer RTP output stream does not stop if system time is set to earlier.
- On CentOS 7 OS: Active TS recording duration is not affected by system time changes.
- Fix for TS recording ERROR: duplicate key value violates unique
constraint "source_pkey" (caused by source_source_id_seq sequence in the
database has wrong last_value).
- Fix for uploading file to TS repository ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for adding service ERROR: duplicate key value violates unique constraint "playlist_pkey".
- Fix for adding service ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for adding service ERROR: duplicate key value violates unique constraint "stream_pkey".
- Fix for AV uploading ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for adding RTP source to AV repository ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for SSU carousel adding ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for SSU carousel group adding ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for uploading file to SSU TS repository ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for Carousel uploading to applications repository ERROR: duplicate key value violates unique constraint "source_pkey".
- Fix for uploading file to SSU carousel ERROR: duplicate key value violates unique constraint "ssu_carousel_file_pkey".
- Fix for adding playlist ERROR: duplicate key value violates unique constraint "playlist_pkey".
- Fix for splitting playlist ERROR: duplicate key value violates unique constraint "playlist_pkey".
Packages changes:
- Split packages file into one packages file for CentOS 6 and one for CentOS 7.
Version 4.6.5.1
Release date: 2020-03-31
Server changes:
- Includes 64 bit RPMs for CentOS 7 as a beta release, installs and runs on CentOS 7.
API changes:
Webconsole changes:
Version 4.6.5.0
Release date: 2020-03-20
Server changes:
- Support for outputting the same transport stream to multiple ASI output ports of the same ASI card.
PMC changes:
- Support for configuring a transport stream to output on multiple output ports of the same ASI output card.
Webconsole changes:
- Improved handling of file time stamps in FTP carousel updates.
- Test the carousel update FTP connection when it is configured.
- Improved handling of FTP usernames and passwords containing special characters, such as backslash.
Version 4.6.4.2
Release date: 2020-03-13
Server changes:
- Includes 64 bit RPMs for CentOS 7 as a beta release.
Version 4.6.4.1
Release date: 2020-03-06
Server changes:
- Uses Xerces-C Version 3.0.1. Old Xerces-C 2.4 can be removed using command rpm -e --nodeps xerces-c.
- Dsmcc-updater: Handle FTP usernames and passwords containing backslashes and/or single quotes correctly.
PMC changes:
- Fix Id Reservation Settings dialog so that the Application ID max
is limited to 65533 (previous limit was 32767). The default value in the
database is 65533 (0xFFFD).
Version 4.6.4.0
Release date: 24.02.2020
Installation changes:
- Installs Playout Web Console.
Version 4.6.3.1
Release date: 14.02.2020
Server changes:
- Support for generating PCR PID packets.
- Incomplete support for PCR PID configurations on the fly, muxer has to be restarted to get the new config in use.
PMC changes:
- Possibility to edit a service's PCR PID and PCR Repetition Rate
(ms) under DVB Services > (select service and click for menu) >
Edit Service > ID settings
Version 4.6.3.0
Release date: 13.02.2020
Server changes:
- Muxer, etc.: Initial support for MPEG-2 AV Streaming feature added when using Multinetwork support.
- Dsmcc-input: New config value dsmcc-generate-default-descriptors
which can be used to turn off default descriptor generation in DSM-CC
type B object carousels.
- Dsmcc-input: Output configured PMT descriptors under the AIT PID in
the PMT table, when Application PMT Descriptors have been added.
- Scheduler: Support for weekly and monthly timers.
PMC changes:
- Add Carousel Identifier Descriptor as an option when editing an application's PMT descriptors.
- Added Generate default descriptors checkbox under Server
> Settings > DSM-CC which can be used to turn off default
descriptor generation in DSM-CC type B object carousels.
- PMC: Add Edit Application PMT Descriptors action in menu for applications in Application Repository. This allows editing the PMT descriptors visible under the AIT PID.
Version 4.6.2.7
Release date: 22.01.2020
Server changes:
- EIT: Added configuration flag eit-debug, and eit-update-debug which
are 0 by default (false). Because of this there can be less EIT related
logging by default, while more logging can be used if necessary.
Version 4.6.2.6
Release date: 21.01.2020
Server changes:
- EIT: Fix bug where sometimes text would be missing in the Extended Event Descriptors due to conversion errors from UTF-8.
- EIT: When converting EPG data in UTF-8 format to output encodings,
e.g. to ISO-8859-2, fit more output characters into each Extended Event
Descriptor.
- EIT: Logging of UTF-8 characters that could not be converted to the
a service's text encoding e.g. "service id 2012, event id 346: '„'
(bytes e2 80 9e) failed to convert to ISO-8859-2"
- EIT: Bugfix for crash caused by bug introduced in version 4.6.0.9.
Version 4.6.2.5
Release date: 09.01.2020
Server changes:
- Dsmcc-update: support for HTTP.
- Replication: Rewritten copy_config.sh and other scripts. Now all
the replication scripts take relevant host information as arguments,
rather than IP numbers being inside the script as a hardcoded variable.
The copy_config.sh script now returns 0 on success and 1 on failure.
Version 4.6.2.2
Release date: 28.11.2019
Server changes:
- Muxer: logging of timestamps for stream events.
Version 4.6.2.1
Release date: 26.11.2019
PMC changes:
- Bugfix for broken pipe problem when modifying network.
- Configuration possibility in pmc15.xml config file to use
non-default ports for scheduler, admin, admin-http, eit-update and ssh.
Version 4.6.2.0
Release date: 16.11.2019
Server changes:
- EIT update: Icareus data source rating value can now be specified
as a hexadecimal number with a 0x prefix, e.g. <rating
country_code="902" rating="0x0e" position="0"/>
- DSMCC input: MHP carousels get a default data broadcast id descriptor.
- DSMCC update: new service for dynamically updating carousel contents.
Version 4.6.1.2
Release date: 22.10.2019
Server changes:
- EIT update: Icareus data source and XMLTV data source content-type
value can now be specified as a hexadecimal number with a 0x prefix.
- EIT update: Added config option eit-update-source-xmltv-oiv-filtering.
- DSM-CC input: Make a log entry of stream event object, event and payload, when it is sent.
Version 4.6.1.0
Release date: 04.10.2019
Server changes:
- EIT update: Improved Jade EPG source parser.
- Improved stream event debug logging for webhandler.
- Improved listing of carousel stream info, including source type and subtype.
PMC changes:
- PSI/SI editor bug fix for NIT and NIT other networks.
Version 4.6.0.8
Release date: 20.09.2019
Server changes:
- EIT: "EIT days to output" option now works so that 0 days means
show no events, 1 means show only today's events (1 day) etc.
Previously 0 meant show only today's events.
- EIT update: Fast scanning of source directory for input files.
PMC changes:
- PMC does not ask for playout password as often as before.
Version 4.6.0.7
Release date: 13.09.2019
Server changes:
- EIT: Past events that overlap UTC time 0:00 (midnight) and end
during the current day are now added to the EIT schedule. In previous
versions these would not be in the schedule. Added config option
eit-schedule-generate-before-midnight-event which is true by default,
which can be used to revert to the old behaviour.
- EIT update: Improved logging.
PMC changes:
- Overwrite events checkbox removed from TitanTV updater EIT config,
because the option is not supported in the TitanTV EPG input (the parser
always discards old events for a service and writes the new ones from
the xml file to the database).
Version 4.6.0.5
Release date: 23.08.2019
Server changes:
- EIT update: ASI and IP EPG data sources now read EIT other schedule tables in addition to the actual tables.
- EIT update: ASI and IP EPG data sources can now collect EPG data from multiple transport streams when using default settings.
- EIT: outputs Component Descriptor and Content Identifier Descriptor
in EIT tables if those are present in the input format (tested with IP
data source).
- EIT: Bug fix for the situation where EIT crashes because a top
level network does not exist (can happen when upgrading from Playout
4.4.)
- EIT: Bug fix: Output content and parental rating descriptors only
once per event, not once for each description language present in the
event.
- Playout is compiled against DekTec DTAPI version 5.34.0.120.
PMC changes:
- ASI and IP EIT default settings can now be configured to collect data from multiple transport streams.
Version 4.6.0.3
Release date: 13.08.2019
Server changes:
- Bug fixes for EIT update and generation.
Version 4.6.0.1
Release date: 07.08.2019
Server changes:
- EIT generation now converts UTF-8 to ISO-8859-7 (Greek) more correctly and fits more characters into each event descriptor.
Version 4.5.4.6
Release date: 14.06.2019
PMC changes:
- Edit Network TS dialog now shows the EIT Schedule bit rate per service (bit/s) value correctly.
Version 4.5.4.5
Release date: 05.06.2019
Server changes:
- DSMCC carousel file updates happen only 5 seconds or more after any
file in the carousel has changed on disk. The purpose is to avoid a
race between e.g. an FTP upload of carousel files and updating the
carousel files into the carousel.
Version 4.5.4.4
Release date: 23.05.2019
Server changes:
- Large DSMCC carousels with multiple DownloadInfoIndication structures get improved transaction id handling
- Carousel debug dump files (in /tmp) are only written when the
carousel changes (avoids making a lot of files with the same content in
/tmp)
Version 4.5.4.3
Release date: 20.05.2019
Server changes:
- Thread and socket handling refactored in playout-admin for TCP and HTTP requests
Version 4.5.4.2
Release date: 10.05.2019
Server changes:
- DSMCC carousel generator uses MD5 sums to determine if carousel files have been updated, instead of using file timestamps
- DSMCC carousel generator updates DII module versions more correctly
Version 4.5.4.1
Release date: 03.05.2019
Server changes:
- Harris BCM EPG data source
- NIT descriptors added in PMC are now are put into the output in multinetwork
PMC changes:
- Harris BCM EPG data source
- Sort server menu to make it tidier
MD5SUMS:
Version 4.5.4.0
Release date: 18.04.2019
Server changes:
- TV-Anytime EPG data source
- DSMCC carousel generator uses a different transaction id for each
DII (DownloadInfoIndication) in a carousel, if multiple DII's are
present
- DSMCC carousel generator only adds an Application Signalling
Descriptor to the carousel PMT (visible under the AIT PID) if the user
has not specified one in PMC, this lets the user override the default
descriptor if it is not suitable
PMC changes:
- TV-Anytime EPG data source
MD5SUMS:
Version 4.5.3.10
Release date: 08.03.2019
Server changes:
- EIT p/f events bug fixed.
- Muxer fillbuffer bug fixed.
- Maximum AIT application Id raised from 0x3FFF to 0xFFFD.
- Fixed carousel identifier descriptor and added default data broadcast id descriptor for MHEG-5 object carousels.
- Removed DVB-H functionality as obsolete. Removed services
playout-dvbh-esg, playout-esgen-middle, playout-esgen-player,
playout-flute-streamer, playout-ip-input, playout-ip-streamer.
- Removed playout-merlin.
PMC changes:
- Show multiple actual network ids, if present, under an original network id in the server tree view.
- Allow setting the same IP and port, but different output interface for UDP output 1 and UDP output 2.
Version 4.5.3.9
Release date: 04.02.2019
Server changes:
- Jade XML has event start times in local time. Fix Jade XML EPG
autoupdater, previously it would interpret the start times in the file
as UTC time.
PMC changes:
- Fix NIT menu for single network license.
Version 4.5.3.8
Release date: 25.01.2019
Server changes:
- EIT events are generated into the transport stream, with event
start times adjusted by the new EPG event start time offset in minutes
(event times in TS are in UTC time zone).
- Campaignhandler: duplicate trigger filtering.
PMC changes:
- In Edit Service tab EIT properties, added configure option EPG event time offset in minutes.
Version 4.5.3.7
Release date: 22.01.2019
Server changes:
- Single network bug fix: allocate a PMT PID when adding a service,
PMT PID cannot be 0 on single network as it is not attached to a network
in the same way as in multinetwork.
- Muxer, EIT and EIT update open fewer DB connections. This speeds up overall performance.
- A fix in EIT update cleanEvents to remove all duplicate events that
have the same start time as a new inserted event (same fix as in
4.4.1.14)
- CampaignHandler gets displayTimes feature.
- Added support for BAT tables containing multiple Bouquets
- UDP multicast output stays on the same interface, previously the
output could switch over to another interface (e.g. from eth1 to eth0)
if the configured output interface loses connection, and when the
interface came back up, the output would not switch back.
- TitanTV EIT update fix for spanish language, correct code is "spa", not "esl".
- BAT, SDT, NIT and EIT p/f and EIT schedule tables can be outputted on tunneling pids.
- Logging puts the thread ID in each log message.
PMC changes:
- Allow configuring BATs with multiple bouquets in menu: PSI/SI > Edit BAT
- Change in nitDescriptors.xml to allow specifying the Satellite
Delivery System Descriptor modulation field parts roll_off,
modulation_system and modulation_type.
Installation changes:
- The playout user is configured to have /bin/bash as shell and not
/sbin/nologin. This is needed so the new SSH based PMC login works. In
addition, changes have been made to the installation script setup.sh to
allow playout ssh login.
Version 4.5.3.6
Release date: 31.12.2018
Server changes:
- Memory consumption optimization for EIT events handling.
- EIT generation uses much less memory, this makes Playout support much bigger EIT schedules.
- DB connection socket optimizations to massively decrease the amount
of opened sockets to postgresql database. This improves server
performance and PMC login times.
- Muxer bit rate overflow bug fixed. The bug prevented tables, e.g. EIT schedule parts being generated bigger than 268 megabytes.
PMC changes:
- Tunneling tab in Edit Network TS dialog, allowing the specification
of the Tunneling network TS (what TS to tunnel to) and tunneling PIDs
for NIT, SDT, BAT, TDT, TOT, EIT. The tunneling tab can be enabled using
a specific license.
- PMC would hang on the splash screen if the .playout/pmc15.xml file
is empty. If it is empty, just remove it as it doesn't contain any info
anyway.
- RPM spec arch changed from i586 to noarch.
Version 4.5.3.0
Release date: 15.11.2018
Server changes:
- EIT schedule can now be split into parts which can be sent with different repeat rates.
- TitanTV EIT autoupdate can now automatically add services.
- All maximum repeat rates are changed from 300,000 ms (5 minutes) to 100,000,000 ms.
- EIT update added autoupdater for Jade XML format.
- Campaignhandler generalization for trigger handling and some bug fixes for http query response handling.
- TitanTV EIT update now supports parental ratings.
- Support for customer specific Show identifier descriptor.
PMC changes:
- Performance optimization for tree handling to speed up loading of services etc.
- A default value for EIT days to output can be specified.
- For each service the default EIT days value is selected by default but one can also specify a service specific EIT days value.
- IP and ASI input sources allow setting the required EIT PID of the
input, so something else than the standard EIT PID 18 can be used in the
input.
- New splash screen image.
Version 4.5.2.3
Release date: 2.10.2018
Server changes:
- A bug related to object carousel restarting once every 26,5 hoursfixed
- A bug related to unwanted stream_identifier_descriptor fixed
- A bug related to unwanted DataBroadcastIdDescriptor fixed
PMC changes:
- Fixed a bug related to transparency settings for pbject carousel collections
Version 4.5.2.2
Release date: 1.10.2018
Server changes:
- AIT default repetition rate changed from 2000ms to 200ms.
- EIT days to output can be specified per service. Previously the value was hardcoded as present day plus 6 days.
- Campaignhandler: Empty trigger with current time support.
- NIT doesn't split transport streams to new section and ignores those that doesn't fit in one section.
- NIT CRC bug fix.
- EIT update added 2 new autoupdaters.
- Reset TS input clock correctly in MuxerOutputMultinetwork.
PMC changes:
- PMC uses playout password and not root password for login.
- PMC uses SFTP (SSH) for PMC login and many other functions instead
of FTP. The SSH support on Java is provided by the jsch-0.1.54.jar
library.
- In Edit Network TS window new Generation and Rates options for options such as Generate EIT Schedule 0-3, etc.
- Allow specifying EIT schedule segment groups using combo boxes.
- Fix bug where DSM-CC collections can't be set as transparent.
- Support for new EIT sources.
Version 4.5.1.1
Release date: 15.2.2018
Server changes:
- support for Addressble TV
- DownloadInfoIndication support for big object carousel data amounts
- support for text format EIT autoexport
- support for EIT API key
- support for SDT tables bigger than 1024 bytes
- support for NIT tables bigger than 1024 bytes
- "magic-bit" support for PMT descriptor added
- open SSL key length increased to 2048 bits
- bug fixes for replication handling
- bug fixes for exporting/importing of configuration
- bug fixes for SDT table producing
- bug fixes for EIT table producing
PMC changes:
- support for EIT API key
- horizontal bar added to long lists that didn't fit to the screen
- added status polling for the object carousels
Version 4.4.1.14
Release date: 2.1.2019
Server changes compared to 4.4.1.12:
- Added support for BAT tables containing multiple Bouquets
- A fix in EIT update cleanEvents to remove all duplicate events that have the same start time as a new inserted event
PMC changes:
- Allow configuring BATs with multiple bouquets in menu: PSI/SI > Edit BAT
Version 4.4.1.12-patch1
Release date: 22.12.2017
Server changes:
New Multi-network structure

| The
multi-network structure has now been changed so that instead of one
Actual network, several Actuals networks can be created for one network.
Each Actual network carry one transport stream.
The Other network struture has also now one more layer. This means that network can have several Other
networks, and each of them can have several sub Other networks with each of them carrying one transport stream. |
support for periodic timestamp DIN events

| This
new feature is supported for "Do it now" (DIN) stream events. When some
value is given to the "Sending period in seconds" edit field, and
"Start sending event" is selected, the Playout server starts to send
DIN events with timestamp (UNIX Epoch time) repeatedly with given interval.
Sending this stream event can be stopped by selecting "Stop sending event". |
DSM-CC stream data_broadcast_id bug fix

| Now dataBradCastId has a value 0x123.
|
DSM-CC stream NPT tag bug fix

| Removed the default reference to the STR_NPT_USE component tag from stream events.
|
- changes for default DSM-CC and DMS-CC-HBBTV descriptors
- application id maximum value increased from 32767 to 65533
- some bug fixes for DSM-CC and AIT
PMC changes:
- New Multi-network structure
- support for periodic timestamp DIN events
- enhancements for AIT descriptors
Version 4.4.1.12
Release date: 23.02.2016
Server changes:
- New parameter "EIT Schedule bit rate per service" supported for single and multi network environment
PMC changes:
- New field "EIT Schedule bit rate per service" added for RATES -TAB
Version 4.4.1.11
Release date: 09.09.2015
Server changes:
PMC changes:
Version 4.4.1.10
Release date: 10.07.2015
Server changes:
- EIT PID database configuration
PMC changes:
- MHEG-5 app configuration
- added more service types
- added LCN descriptor v1/v2
- add "Content descriptor" to SDT
- Event "Start time" column resize problem
Version 4.4.1.9
Release date: 19.03.2015
Server changes:
- Replication status and information can be received
- Icareus Data Source parameters are checked only when needed
- Icareus Data Source username and password parameters can contain special characters
- XMLTV Data Source username and password parameters can contain special characters
- Barco Data Source username and password parameters can contain special characters
- CSV Data Source username and password parameters can contain special characters
- Mediadata Data Source username and password parameters can contain special characters
- TMS Data Source username and password parameters can contain special characters
- TVPPolonia Data Source username and password parameters can contain special characters
- Start and stop of Data Sources was fixed
- Decktec ASI Input/Output cards detection was fixed
- Replication scripts were updated
PMC changes:
- Replication status and information can be shown
- Icareus Data Source parameters are checked only when needed
- New network parameters are checked only when needed
Version 4.4.1.8
Release date: 09.02.2015
Server changes:
- Replication script fix
- Configuration import fix
- Carousel fix
Version 4.4.1.7
Release date: 27.01.2015
Server changes:
PMC changes:
Version 4.4.1.6
Release date: 10.12.2014
Server changes:
PMC changes:
Version 4.4.1.5
Release date: 01.12.2014
Server changes:
- Import/Export of Playout configuration
- The same carousel/AIT/events are used for the same application in each network
- Stream events are sent correctly in multinetwork mode
- In multinetwork changed the order of sending packets in TS: first
cached data (tables, stream events) then input streams (video and
carousels)
PMC changes:
- Import/Export of Playout configuration
- Disabled action to remove AIT from an application
- "Application carousel repository" is renamed by "Application repository"
Version 4.4.1.4
Release date: 24.11.2014
Server changes:
- ASI input EPG data source fix
Version 4.4.1.3
Release date: 02.10.2014
Server changes:
- AIT repetition rate is correctly used in Multinetwork
- Change of AIT repetition rate is applied immediately without application restart in Multinetwork.
- Support for DTU-215
- Dektec cards are automatically detected
- Send SNMP traps to more than 1 SNMP manager
PMC changes:
- Support for DTU-215
- URL for HbbTV applications now can hold parameters
Version 4.4.1.2
Release date: 05.09.2014
Server changes:
- 'Always send application pids' feature
PMC changes:
- 'Always send application pids' feature
Version 4.4.1.1
Release date: 26.08.2014
Server changes:
- Support for sending stream events using Web services API
- Dektec DTA-115 support
- Dektec DTA-110 is not supported anymore
Version 4.4.0.18
Release date: 18.06.2013
Server changes:
Version 4.4.0.17
Release date: 17.03.2013
Server changes:
- 'send-carousel-for-http-apps' configuration parameter
- 'cache-root-password' configuration parameter
PMC changes:
- 'cache-root-password' configuration parameter
- support KAON/Fortis STB
- fixed long url issue for HbbTV apps
- EPG Parsing log view
Version 4.4.0.16
Release date: 27.02.2013
Playout software package was ported to CentOS 6.3
Server changes:
- Latest Dektec driver for CentOS 6.3
- Multinetwork ASI output
- BarcoXML data source
PMC changes:
- Multinetwork ASI output
- BarcoXML data source
Version 4.4.0.15
Release date: 12.12.2013
Server changes:
- AIT/Carousel multinetwork support
PMC changes:
- AIT/Carousel multinetwork support
Version 4.4.0.14
Release date: 01.05.2013
Server changes:
PMC changes:
Version 4.4.0.13
Release date: 07.03.2013
Server changes:
- Dektec DT-2111 supported
- EIT P/F running status implemented
PMC changes:
Version 4.4.0.12
Release date: 13.02.2013
Server changes:
PMC changes:
Version 4.4.0.11
Release date: 13.12.2012
Server changes:
- Updated multinetwork output
- playout-muxer OOM fix
PMC changes:
Version 4.4.0.10
Release date: 07.11.2012
Server changes:
- TribuneMediaServices data source
- Network/Services limitation
- multinetwork SSU support
PMC changes:
- Settings for TribuneMediaServices data source
- Settings for Network/Services limitation
- Settings for multinetwork SSU support
Version 4.4.0.9
Release date: 13.09.2012
Server changes:
- CSV Data source
- Multinetwork repetition rates
- Service logo feature
PMC changes:
- Settings for CSV Data source
- Settings for Multinetwork repetition rates
- Import XMLTV and CSV using PMC
- T2 delivery system descriptor
- Settings for Service logo feature
Version 4.4.0.8
Release date: 13.09.2012
Server changes:
- XMLTV Autoupdater: support for events without the stop time
- AV Fake Streams: keeps audio/video type of the fake stream
PMC changes:
- Multinetwork: can add a service to a network through right click menu
- AV Fake Streams: keeps audio/video type of the fake stream
Version 4.4.0.7
Release date: 13.08.2012
Server changes:
- XMLTV
- AV Streams Simulations
PMC changes:
- Settings for XMLTV
- Settings AV Streams Simulations
Version 4.4.0.5
Release date: 22.05.2012
Server changes:
- EPG XML Icareus data source files can be taken from the internet
- Bug fixed: very big event description would crash the EIT module on EIT P/F generation
- EIT tables generation can be enabled/disabled
PMC changes:
- Settings for EPG XML Icareus data source
- EIT tables generation in PSI/SI settings
Version 4.4.0.4
Release date: 26.04.2012
Server changes:
PMC changes:
Version 4.4.0.3
Release date: 29.02.2012
Server changes:
- Two independent IP outputs for the multiplexer
- Pure UDP output support
PMC changes:
- Second independent IP output in the multiplexer settings
- UDP/RTP selection in the multiplexer settings
Version 4.4.0.2
Release date: 11.10.2011
Server changes:
- Icareus Data Source feature for EIT Server
- BTS Data Source feature for EIT Server
PMC changes:
- Settings for Icareus updates once per day or week
- Settings for BTS updates once per day or week
Version 4.4.0.1
Release date: 28.09.2011
Server changes:
- Corrected the DSMCC carousels - unlimited number of applications can be delivered
- DekTec ASI/SDI PCI Express adapter DTA-2145 is supported
Version 4.4.0.0
Release date:18.04.2011
Server changes:
PMC changes:
Version 4.3.2.7
Release date: 01.11.2010
Server changes:
- Changed Video Server default playlist management.
PMC changes:
- Increased timeout for FTP file upload
Version 4.3.2.6
Release date: 04.10.2010
Server changes:
PMC changes:
- Added separate create carousel action for HTTP transported carousels (HbbTV)
- Added support for HbbTV descriptors in 'Edit AIT' dialog
- Added EIT settings to control autoupdate of EPG from Mediadata.org
Version 4.3.2.5
Release date: 22.09.2010
Server changes:
PMC changes:
Version 4.3.2.4
Release date: 28.05.2010
Server changes:
- EPG Sales updates once per day or week
PMC changes:
- Settings for EPG Sales updates once per day or week
Version 4.3.2.3
Release date: 23.04.2010
Server changes:
PMC changes:
Version 4.3.2.2
Release date: 23.03.2010
Server changes:
- EPG Sales Data Source feature for EIT Server
- Extended Event Descriptor implemented for EIT Event
PMC changes:
- EIT Settings for EPG Sales Data Source feature
- Long description for Event information
Version 4.3.2.1
Release date: 05.03.2010
Server changes:
- Carousel files scheduled for update are updated only when the files are modified